Details
-
Type:
Task
-
Status:
Done
(View Workflow)
-
Priority:
Normal
-
Resolution: Unresolved
-
Labels:
-
Customer:Zain KSA 3.X
Description
Click to add description
Issue Links
- blocks
-
ZKU-94
Huawei RAN_Dumps , XML and NEP data Validation
-
Dear @Bassem Sabbagh,
As per our discussion, we have identified an issue with three nodes in the Huawei case. Specifically, there are duplicate entries for NEName="ARR0519-P1-HUB_SRAN-FON" with different NEType values in the dump. This results in the first entry being parsed correctly, while the second one is ignored in the XML. Note that all physical data for both nodes is identical.
Here are the affected nodes:
Sr. No. Nodes Comment
1 BTS3900_ARR0519-P1-HUB_SRAN-FON Parsing
2 BTS3900_HLH0124-P2_SRAN Parsing
3 BTS3900_UNZ0151-P2_SRAN Ignoring
4 BTS5900_ARR0519-P1-HUB_SRAN-FON Ignoring
5 BTS5900_HLH0124-P2_SRAN Ignoring
6 BTS5900_UNZ0151-P2_SRAN Parsing
Example for the node ARR0519-P1-HUB_SRAN-FON:
1st Dump Snippet:
2nd Dump Snippet:
XML Error Snippet:
Could you please provide your suggestions on how to resolve this issue?
Best regards,
Indrasan