[ACE-675] Getting error on opening *Splice Module* Created: 05/Mar/26  Updated: 12/Mar/26  Due: 06/Mar/26  Resolved: 10/Mar/26

Status: Closed
Project: ACE
Component/s: UCMDB
Affects Version/s: UCMDB 4.0.0.15
Fix Version/s: None

Type: Bug Priority: Normal
Reporter: Nemer Richmany Assignee: Nemer Richmany
Resolution: Fixed Votes: 0
Labels: UCMDB_WEB
Remaining Estimate: Not Specified
Time Spent: Not Specified
Original Estimate: Not Specified

Attachments: JPEG File Image.jpeg    
Customer:
Mobinets
Planned Start:

 Description   

Platform: http://65.108.79187:6016
Bug description: When we click on the following path: Inventory/Outside Plant (OSP)/Passive Equipment/Splice Module



 Comments   
Comment by Mohamad Ghorghar [ 05/Mar/26 ]

Apply 20260116_UPDATE_SPLICE_MODULES_VIEW.sql script that exist in patch 4.0.0.15

Comment by Nemer Richmany [ 10/Mar/26 ]

This bug still exists and has not been resolved yet. Please re-check

Comment by Omar Kamalddine [ 11/Mar/26 ]

Script has been successfully applied.
It is now ready and can be tested directly.