[LS-888] FO Buffer Tube and FO Strand issue Created: 19/Jan/26  Updated: 23/Jan/26  Due: 23/Jan/26  Resolved: 23/Jan/26

Status: Closed
Project: L3 Support
Component/s: NEP
Affects Version/s: None
Fix Version/s: None

Type: CR Priority: Normal
Reporter: Jharna Thakur Assignee: Bassem Sabbagh
Resolution: Fixed Votes: 0
Labels: AI_All_incidents
Σ Remaining Estimate: 0 minutes Remaining Estimate: 0 minutes
Σ Time Spent: 2 days, 7 hours Time Spent: 2 days, 7 hours
Σ Original Estimate: Not Specified Original Estimate: Not Specified

Attachments: File 20260121_ALTER_TABLES_FOBUFFERTUBE_AND_FOSTRAND_ADD_INDEX_COLUMN.sql    
Sub-Tasks:
Key
Summary
Type
Status
Assignee
LS-889 FO Buffer Tube and FO Strand issue De... Technical task Open Bug Khaled Khalil  
LS-896 FO Buffer Tube and FO Strand issue : ... Technical task Open Bug Khaled Khalil  
Customer:
Ooreedo Tunisia
Planned Start:
Planned End:
Actual Start:
Date of Baselining:

 Description   

not able to save FO Buffer Tube and Fo Strand model in xml



 Comments   
Comment by Marwan Kanaan [ 22/Jan/26 ]

Dear @Jharna Thakur and @Bassem Sabbagh,

Kindly note that Fo Buffer Tube and Fo Strand models are now available in ImporterNetwork and can be imported via XML and CSV, either through auto-import or individual file import.

Please note that the import process supports attribute updates only and does not support creation for these two models. Their creation is automatically handled as part of the Fo Cable creation/update process, since the number of Fo Buffer Tubes and Fo Strands is deduced from the Fo Cable type, as already highlighted by Mr. Hassan regarding the relationship between these models.

Furthermore, I have added two new attributes for both Fo Buffer Tube and Fo Strand:

  • Tube Index
  • Strand Index

These attributes:

  • Are auto-deduced during the creation process
  • Cannot be modified
  • Are derived from the naming convention
    • (e.g., Buffer Tube 1 → Index = 1, Buffer Tube 2 → Index = 2, etc.; same logic applies to strands)

These two attributes must be included in the connector, as the update process will not proceed without them.

Additionally, both attributes have been added as columns in the Fo Cable Details Report for Buffer Tubes and Strands, to clearly indicate each index.
Kindly apply patch 3.7.0.1415.

The attached script should be executed to alter the database tables and add the new columns. The Script is also included in the patch.

Best Regards,
Marwan Kanaan I Software Developer