      Description

      When clicking on OSP > Passive Equipment > Splice Module, an error is displayed and the display is blocked>
      Error message in the screenshot.

        Activity

        Hide
        Nouha Mhadhbi added a comment -

        Hi,

        The issue was related to a missing field in the view.
        The field has been added, and the script has been applied to the database.
        It will also be included in patch 0.15.

        Best regards,
        Nouha

        Show
        Nouha Mhadhbi added a comment - Hi, The issue was related to a missing field in the view. The field has been added, and the script has been applied to the database. It will also be included in patch 0.15. Best regards, Nouha