Details
-
Type:
Task
-
Status:
Closed
(View Workflow)
-
Priority:
Normal
-
Resolution: Fixed
-
Labels:
-
Customer:Ooreedo Tunisia
Description
Dear @Jharna Thakur,
As discussed on Friday, please update the rule in connector and share me the updated XML accordingly.
1- SFP is currently being parsed as boards, which needs to be corrected by removing SFP from the board parsing logic and SFP will be parse now in node interfaces.
2- I have updated the FRS accordingly and am attaching it here for reference.
3- For equipment model also updated the FRS & static sheet shared, need to parse the model accordingly.
Best regards,
Indrasan
Activity
- All
- Comments
- Work Log
- History
- Activity
- Links Hierarchy
- Transitions
- Trace
Jharna to define the WL and to be started on 5-3 the second half
Show
Bassem Sabbagh
added a comment - Jharna to define the WL and to be started on 5-3 the second half
The issue for Huawei RAN has now been resolved for the importer ID below, which was shared by @Basant Kumar:
20260406101508_2026-04-06-10.15.08