Details
-
Type:
Bug
-
Status:
Closed
(View Workflow)
-
Priority:
Normal
-
Resolution: Fixed
-
Component/s: None
-
Labels:
-
Customer:Zain KSA 3.X
Description
Dear @Khaled Khalil,
Could you please assign a DEV resource to check and fix the issue mentioned below?
Total 1192 boards of node type BSC only are not being imported into NEP, and there is no error reports related to this issue.
While the total board count (146 for node BSC-394126 for example) matches between XML and NEP for node type BSC (BSC-394126), the issue is that some boards are correctly mapped to their respective cabinet, shelf, and slot, while others are appearing on different shelves in NEP.
For reference, I am sharing an example for one BSC (BSC-394126) with one board type (EMB):
XML Snippet:
Here, the board type EMB is placed in cabinet-1, shelf-1, and slots 26/27.
NEP Snippet:
However, in NEP, it is showing in cabinet-1, shelf-5, and slots 26/27.
Best regards,
Indrasan
Attachments
Issue Links
- blocks
-
ZKU-95
Nokia RAN_Dumps , XML and NEP data Validation_Sub Parent
-
Activity
| Transition | Time In Source Status | Execution Times | Last Executer | Last Execution Date | |||||
|---|---|---|---|---|---|---|---|---|---|
|
5d 18h 37m | 1 | Khaled Khalil | 24/Dec/24 6:53 AM | |||||
|
8s | 1 | Khaled Khalil | 24/Dec/24 6:53 AM | |||||
|
2d 1h 28m | 1 | Mustapha Al-Hage | 26/Dec/24 8:21 AM | |||||
|
3h 37m | 1 | Khaled Khalil | 26/Dec/24 11:59 AM | |||||
|
14d 17h 10m | 1 | Indrasan Yadav | 10/Jan/25 5:09 AM | |||||
|
26s | 1 | Indrasan Yadav | 10/Jan/25 5:09 AM |